lisaann在线观看-销魂老女人老泬-久久久久久久久久久激情-国内日韩免费在线一级片

Your Position: Home > Support > Update Center

Cleaning and Replacement of Dust-proof Net of Vacuum Oil Filter

2019/8/1??????view:

  1. Clean the entrance dust-proof filter

  Tools needed:

  10mm, 17mm open wrench or socket wrench.

  The dirt shield for blocking coarse particles is located at the inlet flange of the pump (7/57). It should be kept clean to avoid a drop in pumping speed.

  The dirt shield is composed of two metal screen sieves. The outer screen can be seen when the intake pipeline is removed. If it's only slightly dirty, just remove the dirt from the outside of the network. If the net cover is dirty, remove the import valve orchid. To this end, remove the fastening screw at the top of the cylinder block cover (7/51a-52a), loosen the pump foot at the bottom of the cover (7/94a), and remove the cover.

  Remove four screws and remove the intake flange (7/57) and gasket (7/55).

  Remove the clasp from the intake flange (7/57). Remove two metal screen sieves and wash them with appropriate solvent.

  Reload in reverse order. We recommend replacing the original pad with a new pad (7/55).

  warning

  According to the process involved, hazardous substances may spill over from pumps and oils. Take corresponding measures. Comply with safety regulations.

  Important Notes

  When handling used oil, please observe the relevant environmental regulations!

  Watch out

  Used seals must not be installed; new seals must be installed.

  2. Check the anti-return valve

  Tools needed:

  10mm, 17mm open wrench or socket wrench.

  Adjustment ring: 71072333

  To ensure the normal operation of the pump, keep the anti-return valve clean and clean. If the process gas inhaled by the pump contains a large amount of dust or dirt, we strongly recommend that a dust filter be installed before the pump inlet (see Section 1.4).

  First remove the intake pipe.

  Then remove the fastening screw at the top of the cylinder block cover (7/51a-52a), loosen the pump foot at the bottom (7/94a), and remove the cover.

  Remove four screws and remove intake flange (7/57) and gasket (7/55).

  Remove spring and oil return valve.

  If the anti-return valve is too tight, press the spring a little. The upper edge of the anti-ventilation line should be about 1-2 mm from the lower side of the intake port.

  Reload the intake. We recommend replacing the new gasket (7/55).

  The flat side of the anti-return valve is down.

  The large diameter end of the spring is downward and the small diameter end is opposite to the flat side of the anti-return valve. The anti-return oil valve has a ring of sealing line with one side facing up.

  warning

  According to the process involved, hazardous substances may spill over from pumps and oils. Take corresponding measures. Comply with safety regulations.

  Importantly, when dealing with used oil, please observe the relevant environmental regulations!

  Be careful not to install used seals; be sure to install new seals.


甘泉县| 柞水县| 南陵县| 二连浩特市| 武川县| 临邑县| 咸丰县| 澄江县| 赫章县| 登封市| 马鞍山市| 贵州省| 永康市| 潞城市| 海晏县| 林州市| 浪卡子县| 沧源| 葫芦岛市| 叶城县| 瑞安市| 佛冈县| 灌阳县| 阿克陶县| 彭泽县| 荆门市| 高唐县| 彝良县| 精河县| 达拉特旗| 新巴尔虎左旗| 乐陵市| 含山县| 灵璧县| 安达市| 米泉市| 石河子市| 新干县| 怀来县| 黄梅县| 冀州市|